Beskrivelse
1Control Module: When the current is too large or too small, the relay switch will control line to connect and disconnect, or give a signal. 2Detection Range: Can conveniently detect DC 730V current between 010A, and the detection voltage is equal to the input power voltage. 3Practical Using: Comes with error calibration function, and the display can also be turned off for a long time to reduce power consumption. 4High Accuracy: The current detection module has a high accuracy up to 0.01A, which ensures small error for easier and more efficient work. 5Easy Operation: Digital display enables a clear view to the work status, and the simple operation will help to prevent the stalling as well.
Item Type: DC Current Detection ModuleProduct Model: YYI-2. When the detection current is too large or too small, the control relay switch will control the circuit to be on or off, or give a signal; Detection Range: DC 7-30v current between 0-10A, the detection voltage is equal to the input power voltage; Detection Accuracy: 0.01A (10mA)Error Calibration: With error calibration function, and the display can be turned off for a long time to reduce power consumption; Standby Current: About 20mA; Relay Output: Can control the on and off of DC lines within 10A; Function Description: 1. P-11: When the measured current is greater than I1, the relay is closed; when the measured current is less than I1 again, the relay is disconnected; 2. P-12: When the measured current is greater than I1, the relay is closed; and it will always stay closed until the circuit board is powered off; 3. P-21: When the measured current is greater than I2, the relay is closed; when the measured current is less than I1, the relay is disconnected; 4. P-22: When the measured current is greater than I2, the relay is closed; and it will always stay closed until the circuit board is powered off; 5. P-31: When the measured current is less than I1, the relay is closed; when the current is greater than I2, the relay is disconnected; 6. P-32: When the measured current is less than I1, the relay is closed; and it will always stay closed until the circuit board is powered off; 7. P-41: When the measured current is between I1 and I2, the relay is closed, otherwise the relay is disconnected;8. P-42: When the measured current is between I1 and I2, the relay is closed; and it will always stay closed until the circuit board is powered off; 9. P-51: When the measured current is less than I1 or greater than I2, the relay is closed, otherwise the relay is disconnected; 10. P-52: When the measured current is less than I1 or greater than I2, the relay is closed; and it will always stay closed until the circuit board is powered off; Setting Instructions:1. Power on to display the measured current; (if the measured current terminal is suspended, the number of digital display is normal); 2. The first time K1 is pressed, it takes more than 1 second to be effective to prevent false triggering. The screen displays: P 11: K2 adjustment mode, K3 adjustment function; 3. Press K1 for the second time, the screen flashes: 0.05 means that the value of the threshold I1 is 0.05A; K2 sets I1 plus, K3 sets I1 minus; 4. Press K1 for the third time, the screen flashes: 0.10 means the value of the threshold I2 is 0.1A; K2 sets I2 plus, K3 sets I2 minus; 5. Press K1 for the fourth time, the screen displays the measured current; it means it enters the standby state;6. In standby mode, long press K2 or K3 to fine tune the measured current error.
1 x DC Current Detection Module
-
Fruugo ID:
212810995-453729954
-
EAN:
5328792850630
Produktsikkerhedsinformation
Se venligst produktsikkerhedsoplysningerne, der er specifikke for dette produkt, beskrevet nedenfor
Følgende oplysninger leveres af den uafhængige tredjepartsforhandler, der sælger dette produkt.
Produktsikkerhedsmærker
Sikkerhedsadvarsler:
Carefully reading the instruction manual is the first step towards safe use.
Levering og returnering
Sendes inden for 24 timer
Afsendes fra Kina.
Vi gør vores bedste for at sikre, at de produkter, du bestiller, leveres til dig fuldt ud og i henhold til dine specifikationer. Skulle du dog modtage en ufuldstændig ordre eller andre ting end dem, du bestilte, eller der er en anden grund til, at du ikke er tilfreds med ordren, kan du returnere ordren eller produkter inkluderet i ordren og modtage en fuld refusion for varerne. Se fuld returpolitik
Detaljer om produktoverholdelse
Se venligst overensstemmelsesoplysningerne, der er specifikke for dette produkt, beskrevet nedenfor.
Følgende oplysninger leveres af den uafhængige tredjepartsforhandler, der sælger dette produkt.
Producent:
De følgende oplysninger angiver kontaktoplysningerne for producenten af det relevante produkt, der sælges på Fruugo.
- Guang Zhou Cun Bei Mao Yi You Xian Gong Si
- Guang Zhou Cun Bei Mao Yi You Xian Gong Si
- NanShaQuNanShaJieNanShaSheQuNanWanYiJie177Hao
- Guangzhoushi
- China
- 511455
- Dumpanda486@126.com
- https://www.fruugo.com
Ansvarlig person i EU:
De følgende oplysninger angiver kontaktoplysningerne for den ansvarlige person i EU. Den ansvarlige person er den udpegede økonomiske aktør med hovedsæde i EU, der er ansvarlig for overensstemmelsesobligationerne i forbindelse med det relevante produkt, der sælges til den Europæiske Union.
- GAVIMOSA?CONSULTORIA,?SOCIEDAD?LIMITADA
- GAVIMOSA?CONSULTORIA,?SOCIEDAD?LIMITADA
- CASTELLANA 9144
- Madrid
- Spain
- 28046
- compliance.gavimosa@outlook.com
- https://www.fruugo.com