Trigger Cycle Timer Delay Switch Single Channel Circuit Board Power MOS Tube Control Module Relay Module 7?24V

99,00 DKK
+ 75,49 DKK Levering

Trigger Cycle Timer Delay Switch Single Channel Circuit Board Power MOS Tube Control Module Relay Module 7?24V

  • Brand: Unbranded

Trigger Cycle Timer Delay Switch Single Channel Circuit Board Power MOS Tube Control Module Relay Module 7?24V

  • Brand: Unbranded
RRP: 199,00 DKK
Pris: 99,00 DKK
Du sparer: 100,00 DKK (50%)
Sоlgt af:
99,00 DKK
+ 75,49 DKK Levering

På lager

Vi accepterer følgende betalingsmetoder

Beskrivelse

Item Type: Trigger Cycle Timer Delay Switch Product Model: YF-11 Application: Can control solenoid valves, water pumps, motors, light strips, etc. to run freely Input Voltage: DC 7~24V universal Output Power: DC load within 10A can be controlled Time Range: 0.01 second to 999 minutes, any time adjustable Wiring Port Description: 1. DC+: Input the positive pole of the DC power supply 2. DC-: Input the negative pole of the DC power supply 3. IN+: Positive signal input terminal 4. IN-: Negative signal input terminal 5. OUT+: Output positive 6. OUT-: Output negative Button Trigger: (Positive trigger: DC- and in- short circuited, DC+ and IN+ are connected to the button) Or: (Negative trigger: DC+ and in+ short circuited, DC- and IN- are connected to the button) Function List: P-11: Inching (start signal output, output stop when signal disappears) P-12: Self locking (start signal output once, stop signal output again) P-13: Give the signal, the output starts and stops automatically for A second; the trigger is invalid during the delay period P-14: Give the signal, the output will start and stop automatically for A second; trigger to re-timing during the delay period P-15: Give the signal, the output will start and stop automatically for A second; during the delay period, the superposition timer will be triggered P-16: Gives the signal, the output starts and stops automatically for A second; reset is triggered during the delay period P-17: Give the signal, the output starts, the input signal is disconnected, the power is turned off after the start of timing A second, and the signal is kept output during the delay period, and the timing stops P-18: After power on, the output will start, and the power will be turned off after a delay of A seconds; until the next power on P-21: Give the signal, after a delay of A seconds, the output will start P-22: Give the signal, after more than A second, the output starts, the signal disappears, and the output stops P-23: After the signal disappears for more than A seconds, the output starts, there is a signal, and the output stops P-24: There is a signal, the output will start after A second, and the output will stop after the signal disappears for more than A second P-25: When there is a signal, the output will start after more than A second, and the output will stop after more than A second when there is a signal P-26: When there is a signal, the output will stop after A second after the start, and the output will stop after A second after the signal disappears. P-27: Detection of a pulse signal, the output stops; no pulse signal, more than A second output start; (the signal continues or the signal disappears are regarded as no pulse signal) P-28: After power on, after a delay of A second, the output starts until the power is off P-31: After power on, the output starts for A second, stops for B second, infinite loop; power off stops P-32: When there is a signal, start P-31 infinite loop; when the signal disappears, terminate the loop P-33: Give a signal to start P-31 infinite loop; give another signal to terminate the loop P-34: After power on, after a delay of A second, the output will start, and it will stop after closing B seconds P-35: There is a signal, after a delay of A second, the output will start, and it will stop after the pull in for B seconds P-36: There is a signal, the output will start after A second, and stop after B second, the signal disappears, and the timer will be cleared and stopped. P-37: When there is a signal, the output starts and stops automatically for A seconds, and then counts for B seconds after it stops. The signal trigger is invalid within the time A+B. P-38: There is a signal, the output starts and stops automatically for A second, after stopping and counting for B seconds, restarting for A second automatically stops P-41: No action with signal; trigger when signal disappears; disconnect after output start delay A time P-42: The signal disappears, after a delay of time A, the output starts; working time B ends P-43: The signal disappears, after the time A exceeds, the output starts; the working time B ends P-44: After power on, the output will start A time, stop B time; cycle C times and automatically stop. P-45: No action when energized, after signal is given; output starts A time, stops B time; cycles C times and automatically stops; Give signal again, execute again P-46: After giving the signal more than A times, the output will start; keep the output; stop when the power is off P-47: After giving the signal more than A times, the output starts and stops for B seconds P-48: Within C seconds, after continuously giving the signal more than A times, the output starts and stops in B seconds Button Setting Instructions: power on display "----" means entering the standby state; Press K
  • Fruugo ID: 325685022-721032431
  • EAN: 7295624183434

Produktsikkerhedsinformation

Se venligst produktsikkerhedsoplysningerne, der er specifikke for dette produkt, beskrevet nedenfor

Følgende oplysninger leveres af den uafhængige tredjepartsforhandler, der sælger dette produkt.

Sikkerhedsadvarsler: Do not let your children touch this product alone to avoid swallowing or other injuries.

Levering og returnering

Sendt inden for 3 dage

  • STANDARD: 75,49 DKK - Levering mellem kl fre. 03 oktober 2025–fre. 10 oktober 2025

Afsendes fra Kina.

Vi gør vores bedste for at sikre, at de produkter, du bestiller, leveres til dig fuldt ud og i henhold til dine specifikationer. Skulle du dog modtage en ufuldstændig ordre eller andre ting end dem, du bestilte, eller der er en anden grund til, at du ikke er tilfreds med ordren, kan du returnere ordren eller produkter inkluderet i ordren og modtage en fuld refusion for varerne. Se fuld returpolitik

Detaljer om produktoverholdelse

Se venligst overensstemmelsesoplysningerne, der er specifikke for dette produkt, beskrevet nedenfor.

Følgende oplysninger leveres af den uafhængige tredjepartsforhandler, der sælger dette produkt.

Producent:
De følgende oplysninger angiver kontaktoplysningerne for producenten af det relevante produkt, der sælges på Fruugo.

  • 91440300MA5HDL2A4K
  • SHEN ZHEN SHI LAI LI ZHU BAO SHI PIN MAO YI YOU XIAN GONG SI
  • Room B, 21F, Block A, Jingang Huating, 4009 Baoan Avenue, Yantian Community, Xixiang Street, Baoan District, Shenzhen
  • Shenzhen
  • CN
  • 518102
  • 939301410@qq.com
  • 15625700418

Ansvarlig person i EU:
De følgende oplysninger angiver kontaktoplysningerne for den ansvarlige person i EU. Den ansvarlige person er den udpegede økonomiske aktør med hovedsæde i EU, der er ansvarlig for overensstemmelsesobligationerne i forbindelse med det relevante produkt, der sælges til den Europæiske Union.

  • 950891051
  • MJCM SARL
  • 78 avenue des Champs Elysees Bureau 326, 75008 Paris, France
  • Paris
  • FR
  • 75008
  • mjcm190928@gmail.com
  • 0033 767213611