Beskrivelse
Feature:
1. Current Sensor Module: Can easily detect the DC current and control the on and off of relay according to the set limit current.
2. Wide Detection Range: The voltage detection range is 7‑30V, and the current detection range is 0‑30A, meeting various needs.
3. Accurate Measurement: With a high measurement accuracy up to 0.1A, the sensor module has error calibration function as well.
4. Circuit Protection: Used to limit the current in the circuit and protect electrical equipment from damage caused by the current.
5. Convenient Operation: The digital display can be turned off for a long time to reduce power consumption, useful and convenient.
Specification:
Item Type: Current Detection Module
Product Model: YYI-4
Voltage Detection Range: DC7-30V
Current Detection Range: 0~30A
Detection Accuracy: 0.1A (100mA).
Standby Current: About 20mA.
Relay Output: Can control the on and off of DC lines within 30A.
Function: Detect whether the current is too large or too small, control the relay switch to control the line on and off, or give a signal.
How to Use:
No. 1 Operation Instructions:
1. P-11: When the measured current is greater than I1, the relay is closed; when the measured current is less than I1 again, the relay is disconnected;
2. P-12: When the measured current is greater than I1, the relay is closed; it always stays closed until the circuit board is powered off;
3. P-21: When the measured current is greater than I2, the relay is closed; when the measured current is less than I1, the relay is disconnected;
4. P-22: When the measured current is greater than I2, the relay is closed; it always stays closed until the circuit board is powered off;
5. P-31: When the measured current is less than I1, the relay is closed; when the current is greater than I2, the relay is disconnected;
6. P-32: When the measured current is less than I1, the relay is closed; it always stays closed until the circuit board is powered off;
7. P-41: When the measured current is between I1 and I2, the relay is closed, otherwise the relay is disconnected;
8. P-42: When the measured current is between I1 and I2, the relay is closed; it always stays closed until the circuit board is powered off;
9. P-51: When the measured current is less than I1 or greater than I2, the relay is closed, otherwise the relay is disconnected;
10.P-52: When the measured current is less than I1 or greater than I2, the relay will be closed; it will always be closed until the circuit board is powered off.
No. 2 Setting Instructions:
1. Power on to display the measured current(if the measured current terminal is suspended, the number of digital display is normal);
2. The first time K1 is pressed, it takes more than 1 second to effective prevent false triggering. The screen displays: P 11: K2 adjustment mode, K3 adjustment function
3. Press K1 for the second time, the screen flashes 0.05 means that the value of the threshold I1 is 0.05A; K2 sets I1 plus, K3 sets I1 minus;
4. Press K1 for the third time, the screen flashes 0.10 means the value of the threshold I2 is 0.1A; K2 sets I2 plus, K3 sets I2 minus
5. Press K1 for the fourth time, the screen displays the measured current; it means it enters the standby state;
6. In standby mode, long press K2 or K3 to fine tune the measured current error. .
Package List:
1 x Current Detection Module
-
Fruugo ID:
411095577-869929460
-
EAN:
7603816078619
Produktsikkerhedsinformation
Se venligst produktsikkerhedsoplysningerne, der er specifikke for dette produkt, beskrevet nedenfor
Følgende oplysninger leveres af den uafhængige tredjepartsforhandler, der sælger dette produkt.
Produktsikkerhedsmærker
Sikkerhedsadvarsler:
Warning: Please read the product instructions carefully before use to ensure correct use.
Serienummer:
7603816078619
Levering og returnering
Sendt inden for 2 dage
Afsendes fra Kina.
Vi gør vores bedste for at sikre, at de produkter, du bestiller, leveres til dig fuldt ud og i henhold til dine specifikationer. Skulle du dog modtage en ufuldstændig ordre eller andre ting end dem, du bestilte, eller der er en anden grund til, at du ikke er tilfreds med ordren, kan du returnere ordren eller produkter inkluderet i ordren og modtage en fuld refusion for varerne. Se fuld returpolitik
Detaljer om produktoverholdelse
Se venligst overensstemmelsesoplysningerne, der er specifikke for dette produkt, beskrevet nedenfor.
Følgende oplysninger leveres af den uafhængige tredjepartsforhandler, der sælger dette produkt.
Producent:
De følgende oplysninger angiver kontaktoplysningerne for producenten af det relevante produkt, der sælges på Fruugo.
- Wuhan Jinxingkai Network Technology Co., Ltd.
- Wuhan Jinxingkai Network Technology Co., Ltd.
- No. 1-1, Door 57
- Shihua Village
- Qingshan District
- Wuhan
- CN
- 430000
- goldxinks@163.com
- 0086 17786498762
- https://shop01473o1711614.1688.com/page/creditdetail.htm?spm=a261y.7663282.shopNavigation.1.6310755czE9SFQ
Ansvarlig person i EU:
De følgende oplysninger angiver kontaktoplysningerne for den ansvarlige person i EU. Den ansvarlige person er den udpegede økonomiske aktør med hovedsæde i EU, der er ansvarlig for overensstemmelsesobligationerne i forbindelse med det relevante produkt, der sælges til den Europæiske Union.
- None
- Kequ Technology s.r.o.
- Pražákova 1008/69
- Štýřice
- Jihomoravský kraj
- Brno
- CZ
- 63900
- christopher25106@outlook.com
- 420608214795