Beskrivelse
Item Type: Stepper Motor DriverParameter: DM542LMinimum Continuous Output Current: 1AMaximum Continuous Output Current: 4.2AMinimum Input Power Supply Voltage: 18V DCTypical Input Power Supply Voltage: 24V DCMaximum Input Power Supply Voltage: 48V DCMinimum Logic Input Current: 7mATypical Logic Input Current: 10mAMaximum Logic Input Current: 20mAMaximum Power of The Whole Machine: 100WPulse Frequency: 0-200kHzMinimum Insulation Resistance: 500MMaximum Logic Current of Digital Output Port: 100mAMaximum Withstand Voltage of Digital Output Port: 24VCooling Mode: Natural cooling or external radiator. Usage: Avoid dust, oil mist and corrosive gas. Temperature: 0 - 50Ambient Humidity: 40-90% RHOperating Environment Vibration: 10~55Hz/0.15mmStorage Temperature: -20- +65 Interface definition:Terminal 1 Symbol: A+Terminal 1 Name: A Phase Motor Winding+Terminal 1 Wire Color Description: Terminal 2 Symbol: A-Terminal 2 Name: A Phase Motor Winding-Terminal 2 Wire Color Description: Terminal 3 Symbol: B+Terminal 3 Name: B Phase Motor Winding+Terminal 3 Wire Color Description: Terminal 4 Symbol: B-Terminal 4 Name: B Phase Motor Winding-Terminal 4 Wire Color Description: Terminal 5 Symbol: VCCTerminal 5 Name: Input DC Voltage PositiveTerminal 5 Wire Color Description: 18-48V DCTerminal 6 Symbol: GNDTerminal 6 Name: Input DC Voltage NegativeTerminal 6 Wire Color Description: 18-48V DCControl Signal Terminal: Terminal 1 Symbol: DIR-Terminal 1 Name: Direction Negative InputTerminal 1 Description: Signal source +5V~24V universal, no need to connect resistance in series. Terminal 2 Symbol: DIR+Terminal 2 Name: Direction Positive InputTerminal 2 Description: Signal source +5V~24V universal, no need to connect resistance in series. Terminal 3 Symbol: PUL-Terminal 3 Name: Pulse Negative InputTerminal 3 Description: Signal source +5V~24V universal, no need to connect resistance in series. Terminal 4 Symbol: PUL+Terminal 4 Name: Pulse Positive InputTerminal 4 Description: Signal source +5V~24V universal, no need to connect resistance in series. Terminal 5 Symbol: ENA-Terminal 5 Name: Motor Enable Negative InputTerminal 5 Description: When the signal is valid, the motor is in free state and does not stall. Terminal 6 Symbol: ENA+Terminal 6 Name: Motor Enable Positive InputTerminal 6 Description: When the signal is valid, the motor is in free state and does not stall. Terminal 7 Symbol: ALM-Terminal 7 Name: Alarm Signal Negative OutputTerminal 8 Symbol: ALM+Terminal 8 Name: Alarm Signal Positive OutputFault Description: Fault Coding 1: Er01Fault Description 1: Motor OvercurrentSolution 1: Return to factory for inspection. Fault Coding 2: Er02Fault Description 2: Drive OvervoltageSolution 2: Detect whether the motor is short-circuited or reduce the current. Fault Coding 3: Er03Fault Description 3: Hardware FaultSolution 3: Check whether the input voltage is too high. Parameter Monitoring Description:Function Coding 1: L-00Function Description 1: SpeedFunction Introduction 1: Monitor the current speed, voltage and current in real time, check whether the driver works normally, and solve it in time in case of abnormality. Function Coding 2: L-01Function Description 2: Pulse SpeedFunction Introduction 2: Monitor the current speed, voltage and current in real time, check whether the driver works normally, and solve it in time in case of abnormality. Function Coding 3: L-02Function Description 3: Given Pulse NumberFunction Introduction 3: Monitor the current speed, voltage and current in real time, check whether the driver works normally, and solve it in time in case of abnormality. Function Coding 4: L-03Function Description 4: UselessFunction Introduction 4: Monitor the current speed, voltage and current in real time, check whether the driver works normally, and solve it in time in case of abnormality. Function Coding 5: L-05Function Description 5: Driver Fault CodingFunction Introduction 5: Check the number of received pulses in real time to determine whether the motor is out of step.Description of Common Function Coding:Function Coding 1 Parameter Setting: Number of subdivided pulses. Function Coding 1: P-02Function Description 1: 200-51200 arbitrary setting, 2000 in default. Function Coding 2 Parameter Setting: Open loop current percentage. Function Coding 2: P-10Function Description 2: 50%, 8A x 50%=4AFunction Coding 3 Parameter Setting: JOG operation. Function Coding 3: JOGFunction Description 3: Enter JOG and press to jog. Function Coding 4 Parameter Setting: Motor direction. Function Coding 4: P-18Function Description 4: 0 reverse, 1 forward. Function Coding 5 Parameter Setting: Restore to default. Function Coding 5: S-20Function Description 5: Set to 1 to restore default settings. Main Function Parameters of Zone P:P-00: Current loop proportional gain P, 1~327671500P-01: Current loop integral gain I, 2~32766200P-02: Subdivision setting, 200~512002000P-09: Percentage of holding current, 0~100, 40P-10: Percentage of open-loop curre
-
Fruugo ID:
207011739-440618204
Produktsikkerhedsinformation
Se venligst produktsikkerhedsoplysningerne, der er specifikke for dette produkt, beskrevet nedenfor
Følgende oplysninger leveres af den uafhængige tredjepartsforhandler, der sælger dette produkt.
Sikkerhedsadvarsler:
WARNING: TO AVOID DANGER OF SUFFOCATION, KEEP THIS PLASTIC BAG AWAY FROM BABIES AND CHILDREN.
Levering og returnering
Sendes inden for 24 timer
Afsendes fra Kina.
Vi gør vores bedste for at sikre, at de produkter, du bestiller, leveres til dig fuldt ud og i henhold til dine specifikationer. Skulle du dog modtage en ufuldstændig ordre eller andre ting end dem, du bestilte, eller der er en anden grund til, at du ikke er tilfreds med ordren, kan du returnere ordren eller produkter inkluderet i ordren og modtage en fuld refusion for varerne. Se fuld returpolitik
Detaljer om produktoverholdelse
Se venligst overensstemmelsesoplysningerne, der er specifikke for dette produkt, beskrevet nedenfor.
Følgende oplysninger leveres af den uafhængige tredjepartsforhandler, der sælger dette produkt.
Producent:
De følgende oplysninger angiver kontaktoplysningerne for producenten af det relevante produkt, der sælges på Fruugo.
- CREA
- CREA
- 1-3 Boulevard Charles de Gaulle Colombes 92700 FR
- Colombes
- FR
- 92700
- xmchymx@outlook.com
- 86-13312976782
- https://www.fruugo.co.uk/shanxi-tengda-network-technology/m-14879
Ansvarlig person i EU:
De følgende oplysninger angiver kontaktoplysningerne for den ansvarlige person i EU. Den ansvarlige person er den udpegede økonomiske aktør med hovedsæde i EU, der er ansvarlig for overensstemmelsesobligationerne i forbindelse med det relevante produkt, der sælges til den Europæiske Union.
- E-CrossStu GmbH
- E-CrossStu GmbH
- Mainzer Landstr.69,60329 Frankfurt am Main,Hessen, Deutschland
- Frankfurt am Main
- DE
- 60329
- E-CrossStu@web.de
- +4969332967674
- https://www.fruugo.co.uk/shanxi-tengda-network-technology/m-14879