Spectrum Analyzer MF/HF/VHF/UHF Input 0.1-350MHz, UHF 240-960MHz Signal Generator Clear Images And Sensitive Operation

1.449,00 DKK
GRATIS Levering

Spectrum Analyzer MF/HF/VHF/UHF Input 0.1-350MHz, UHF 240-960MHz Signal Generator Clear Images And Sensitive Operation

  • Brand: Unbranded
Sоlgt af:

Spectrum Analyzer MF/HF/VHF/UHF Input 0.1-350MHz, UHF 240-960MHz Signal Generator Clear Images And Sensitive Operation

  • Brand: Unbranded

1.449,00 DKK

Spar 750,00 DKK (34%)

Vejl. Pris

2.199,00 DKK
På lager
GRATIS Levering
Sоlgt af:

1.449,00 DKK

Spar 750,00 DKK (34%)

Vejl. Pris

2.199,00 DKK
På lager
GRATIS Levering

Vi accepterer følgende betalingsmetoder

Beskrivelse

Absolute maximum input level overview - Absolute maximum input level without attenuation: +10 dBm - Absolute maximum input power with 30 dB attenuation: +20 dBm for a short time - Input interface point of third order modulation products (IIP3) with 0 dB attenuation: +15 dBm - 1 dB compression point at +2 dBm with 0 dB attenuation Why this matters - Clear protection for your downstream stages: defined input limits help prevent damage and maintain system reliability during testing and operation. - Predictable linearity for strong conversion tasks: IIP3 and compression points give you a reliable picture of how the signal will behave through the conversion path. - Flexible handling of high level signals: a 30 dB attenuation option allows short duration exposure to higher input powers without immediate risk to the core path. - Simple, robust performance metrics: compact set of well-defined specifications makes it easier to plan, test, and verify RF front-end behavior. Key benefits and what you get - Robust input handling: precise absolute maximums tell you how much signal you can apply without attacking system integrity. - Linearity and intermodulation visibility: IIP3 specification at 0 dB attenuation (+15 dBm) provides a clear indicator of third-order distortion performance. - Compression awareness: 1 dB compression point at +2 dBm (0 dB attenuation) defines headroom before nonlinear compression occurs. - Attenuation option for protection during testing: 30 dB attenuation allows higher input power to be applied briefly (+20 dBm) without exceeding critical limits. How it fits in a system - Function: RF input interface with defined power handling and linearity points tailored for strong conversion applications. - Compatibility: designed to integrate into RF signal chains that require known input thresholds, IIP3 guidance, and predictable compression behavior. - Performance focus: selects and preserves essential nonlinear and saturation characteristics to support accurate testing, calibration, and evaluation of conversion stages. Practical use scenarios - Scenario 1: Lab testing of a high-level RF front end - Use the 30 dB attenuation path to tolerate short surges up to +20 dBm during bench tests. - Monitor IIP3 at 0 dB attenuation (+15 dBm) to assess third-order distortion as you adjust input power. - Reference the 1 dB compression point (+2 dBm) to set safe operating margins for linearity measurements. - Scenario 2: Intermodulation and linearity characterization - Apply dual-tone or multi-tone signals within the IIP3 and compression ranges to quantify intermodulation products and compression onset. - Use the absolute maximums as safety thresholds to avoid damage during high-level excitation. - Scenario 3: Production or field measurement with transient events - Rely on the 30 dB attenuation option for short-duration high-power transients, ensuring protection of sensitive stages while still enabling meaningful test data. - Use the specified IIP3 and compression points to verify consistent performance across units or operating environments. Notes on usage - Respect the absolute maximum input levels to prevent damage to the device and connected components. - Use the 30 dB attenuation path when you anticipate brief high-power signals that exceed the 0 dB attenuation limits. - Refer to the IIP3 and 1 dB compression specifications to design test procedures and signal conditions that reveal the desired linearity and saturation behavior. This description preserves the original specifications and their intended meanings, presented in a clear, customer-oriented format without adding extraneous details.
  • Fruugo ID: 401698204-853799839
  • EAN: 586091970946

Levering og returnering

Sendes inden for 24 timer

  • STANDARD: GRATIS - Levering mellem kl fre. 05 december 2025–tir. 23 december 2025 - GRATIS

Afsendes fra Kina.

Vi gør vores bedste for at sikre, at de produkter, du bestiller, leveres til dig fuldt ud og i henhold til dine specifikationer. Skulle du dog modtage en ufuldstændig ordre eller andre ting end dem, du bestilte, eller der er en anden grund til, at du ikke er tilfreds med ordren, kan du returnere ordren eller produkter inkluderet i ordren og modtage en fuld refusion for varerne. Se fuld returpolitik

Detaljer om produktoverholdelse

Se venligst overensstemmelsesoplysningerne, der er specifikke for dette produkt, beskrevet nedenfor.

Følgende oplysninger leveres af den uafhængige tredjepartsforhandler, der sælger dette produkt.

Producent:
De følgende oplysninger angiver kontaktoplysningerne for producenten af det relevante produkt, der sælges på Fruugo.

  • DelightDew
  • Shenzhen Tumi Technology Co., Ltd.
  • 202-03, Jinhe Building, 8 Xinhe Street, Maan Tang, Bantian
  • Longgang, Shenzhen, Guangdong
  • China
  • Shenzhen
  • CN
  • 518129
  • pettynfnef@outlook.com
  • 13332965772

Ansvarlig person i EU:
De følgende oplysninger angiver kontaktoplysningerne for den ansvarlige person i EU. Den ansvarlige person er den udpegede økonomiske aktør med hovedsæde i EU, der er ansvarlig for overensstemmelsesobligationerne i forbindelse med det relevante produkt, der sælges til den Europæiske Union.

  • Synertrade FR SAS
  • Synertrade FR SAS
  • 9 rue du Bat d'Argent
  • Lyon
  • France
  • Lyon
  • FR
  • 69001
  • info@syner-sarl.cn
  • (+33)774555006
  • https://seller.kuajingmaihuo.com/settle/qualification-service