Beskrivelse
DT-8905D Portable LCD Digital Multimeter Voltage Current Tester
DT‑8905D LCD Digital Multimeter High Accuracy Portable Voltage Current Tester Detector Resistance Capacitance Meter
Item Type: Digital Multimeter
Model: DT-8905D
Material: ABS
Battery: 1 x 9V 6F22 (Battery Not Included)
Application: Widely used in residential, industrial factories, office buildings, home appliance maintenance and testing
Display: 4000 digit LCD display with function indication
Polarity: Automatically distinguish the polarity, (-) negative
Over Range: Expressed as "OL"
Automatic Shutdown: The meter will automatically shut down if there is no operation within 17 minutes. After the automatic shutdown, the meter can only be awakened by pressing the "HOLD" key or turning the knob. The normal measurement rate is 3 times per second
Operating Environment: 0℃~40℃ (41℉~104℉) relative humidity <70%RH
Storage Temperature: -10℃~50℃ (14℉~122℉) relative humidity <80%RH
Maximum Height for Indoor Use: Approx. 2000m / 6561.7ft
Pollution Level: Level 2
DC Voltage
400.0mV
0.1mV
±0.5% of rdg±8dgts
4.000V
1mV
40.00V
10mV
400.0V
100mV
±0.8% of rdg±8dgts
1000V
1V
AC Voltage
400.0mV
0.1mV
±1.2% of rdg±5dgts
4.000V
1mV
40.00V
10mV
400.0V
100mV
700V
1V
DC Current
4.000mA
1uA
±1.2% of rdg±5dgts
40.00mA
10uA
400.0mA
100uA
±1.2% of rdg±8dgts
20.00A
10mA
±2.0% of rdg±10dgts
AC Current
4.000mA
1uA
±3.0% of rdg±8dgts
400.0mA
100uA
±1.5% of rdg±8dgts
20.00A
10mA
±2.0% of rdg±10dgts
Capacitance
4.000nF
1pF
±3.0% of rdg±70dgts
40.00nF
10pF
±4.0% of rdg±8dgts
400.0nF
0.1nF
4.000uF
1nF
400.0uF
0.1uF
Resistance
400.0Ω
0.1Ω
±1.2% of rdg±5dgts
4.000kΩ
1Ω
±1.5% of rdg±5dgts
40.00kΩ
10Ω
400.0kΩ
100Ω
4.000MΩ
1kΩ
±3.0% of rdg±8dgts
40.00MΩ
10kΩ
200.0MΩ
100kΩ
±5.0% of rdg±10dgts
How e:
DC Voltage Measurement:
1. Place the function dial at the VDC (range: 400mV, 4V, 40V, 400V, 1000V) position
2. Insert the black test lead into the negative COM port and the red test lead into the positive V port
3. Touch the tip of the test lead to the object to be tested to ensure that the polarity is correct (red is connected to the positive electrode, and black is connected to the negative electrode)
Warning: Please observe all safety precautions when measuring on the road with wires
1. Set the function dial to VAC (range: 400mV, 4V, 40V, 400V, 700V)
2. Insert the black test lead into the negative COM port and the red test lead into the positive V port
3. Touch the tip of the test lead to the test object
DC Current Measurement:
Note: The measurement time cannot exceed 30 seconds under the condition of 20A, otherwise the meter or test leads may be damaged. During the measurement process, if the current cannot be estimated, start the measurement from the high range, and if necessary, select the low range
1. Insert the black test lead into the negative COM port
2. Measure the current below 400mA DC, set the function dial to DC mA (range: 4mA, 40mA, 400mA), and insert the red test lead into the mA port
3. When measuring DC 20A, set the function dial to the 20A gear and insert the red test lead into the 20A port
4. Disconnect the power supply of the circuit under test, and touch the black test lead to the negative pole of the circuit under test, and the red test lead to the positive pole of the circuit under test
5. Turn on the power
6. Read the current value on the display
AC current measurement
Note: The measurement time cannot exceed 30 seconds under the condition of 20A, otherwise the meter or test leads may be damaged. During the measurement process, if the current cannot be estimated, start the measurement from the high range, and if necessary, select the low range
1. Insert the black test lead into the negative COM port
2. When measuring below 400mA, set the function keyboard to the AC 4mA, 400mA gear position, and insert the red test lead into the mA port
3. When measuring 20A, place the function keyboard in the 20A position and insert the red test lead into the 20A port
4. Disconnect the power supply of the circuit under test, and touch the black test lead to the negative pole of the circuit under test, and the red test lead to the positive pole of the circuit under test
5. Turn on the power
6. Read the current value on the display
-
Fruugo ID:
412921453-872909632
-
EAN:
8401337089133
Levering og returnering
Sendes inden for 24 timer
Afsendes fra Kina.
Vi gør vores bedste for at sikre, at de produkter, du bestiller, leveres til dig fuldt ud og i henhold til dine specifikationer. Skulle du dog modtage en ufuldstændig ordre eller andre ting end dem, du bestilte, eller der er en anden grund til, at du ikke er tilfreds med ordren, kan du returnere ordren eller produkter inkluderet i ordren og modtage en fuld refusion for varerne. Se fuld returpolitik
Detaljer om produktoverholdelse
Se venligst overensstemmelsesoplysningerne, der er specifikke for dette produkt, beskrevet nedenfor.
Følgende oplysninger leveres af den uafhængige tredjepartsforhandler, der sælger dette produkt.
Producent:
De følgende oplysninger angiver kontaktoplysningerne for producenten af det relevante produkt, der sælges på Fruugo.
- Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
- Guangzhoushiyiangongchuangwangluojishu Co.,Ltd.
- Room201,AreaB,No.280,Zhongshan Avenue East
- Huangpu
- Guangzhou
- Guangdong
- China
- 518000
- firzen.pan@gmail.com
- +8619128656319
Ansvarlig person i EU:
De følgende oplysninger angiver kontaktoplysningerne for den ansvarlige person i EU. Den ansvarlige person er den udpegede økonomiske aktør med hovedsæde i EU, der er ansvarlig for overensstemmelsesobligationerne i forbindelse med det relevante produkt, der sælges til den Europæiske Union.
- SUCCESS COURIER SL
- SUCCESS COURIER SL
- CALLE RIO TORMES NUM.1.PLANTA 1,DERECHA.OFICINA3.Fuenlabrada.
- Madrid
- Spain
- 28947
- successservice2@hotmail.com
- +34910602659