Beskrivelse
VU Meter Features:Standard test conditions temperature: 20 Celsius, humidity 70% .
Can also be tested under normal temperature and humidity.The influenza degree pointer at the zero scale to the maximum scale sensitivity of 1000 10% (full scale position);Internal impedance :800 ohm 10%;Insulation impedance meter outside the box plus the electrical circuit with 500V DC plus 50M ohm meter shellElectrical insulation of the circuit impedance is 500V DC voltage test of the insulation value.
Pointer to overlap with the zero-scale tolerance of 1mm balanced meter using a standard position and tilt 90 degrees to allow the error range of 1mm;Pointer to mount the current instant plus three times the full scale current, and slowly reduced to the the electric influenza degree 1/2 reading,The pointer will return to the scale plate within 1/3 scale friction meter coupled with the current, and slowly increase or decrease to a certain value, indicating the point of error range of 1mm,Brake instantly plus scale plate 2/3 of the current value of the pointer indicates the location of the time required for a second or less.VU Meter Special Test:Tests on each interval of five seconds to ten times the full scale current input overload, the action is repeated nine times for each time of 0.5 seconds .After this test, 7-14 to maintain normal.Vibration test meter packaged in the vibration plate 1,000 times per minute, up and down 4mm shock In each direction for 10 minutes.After this test 7-14 to maintain normal impact test meter packaged 30-cm height of fall in 3cm thick wooden board, three-direction test.After this test, 7-14 to maintain normal reliability test the current input of 100,000 calibration points within the limits of current sense is still the standard environmental impact test temperature of 50 Celsius, humidity 85%, for 100 hours, after s test 7-14 to maintain normal.Terminal pull test: terminals must withstand one kilogram tension, sustained 60 seconds will not be affected.VU Meter Others:Using the temperature limits: -10 Celsius to +60 Celsius RH 35 to 85%Storage temperature limits: -20 Celsius to +60 Celsius RH 35 to 85%Do not use the meter in direct sunlight, and PUT the meter in the box to avoid foreign matter into the meter internal.Soldering Condition terminal about 3 mm placed in the temperature of 230 Celsius tin plate, placed 3.5 seconds.After this test, 7-14 to maintain normal,Hand-held soldering to solder temperature 350 Celsius, the terminal contact for 3.5 seconds, the terminal front-end of about 3mm contact with the solder .After this test, 7-14 to maintain normal,Anti-static test in the same direction three times, to characterize the difference between the pointer in the length of the scale in a transparent cover surface to dry nylon 1/3 back to the zero position.Bulb size: 4 blue LED backlighting, parallel to the PCB (3.0-3.2V
80mA)VU MeterThe direction of the pointer swing: left to rightPointer length: 70 1 mm from the center axis to the needle endPointer width: 0.45 0.05 mmColour:Black + BlueMaterial:Zinc cupronickelSize:13.4x9.5x4.5cmPackage
Contents:1 x VU level meterOnly the above package content, other products are not included.Note:
Light and different displays may cause the color of the item in the picture a little different from the real thing.
The measurement allowed error is +/- 1-3cm.
-
Fruugo ID:
237515265-509021196
-
EAN:
9172731637372
Produktsikkerhedsinformation
Se venligst produktsikkerhedsoplysningerne, der er specifikke for dette produkt, beskrevet nedenfor
Følgende oplysninger leveres af den uafhængige tredjepartsforhandler, der sælger dette produkt.
Produktsikkerhedsmærker
Sikkerhedsadvarsler:
WARNING!TO AVOID DANGER OF SUFFOCATION,KEEP AWAY FROM.
Ingredienser:
metal 5.8%
Producentens varenummer:
GD392101
Modelnummer:
GD551920
Serienummer:
GD251175
Batchnummer:
GD719749
Levering og returnering
Sendt inden for 2 dage
Afsendes fra Kina.
Vi gør vores bedste for at sikre, at de produkter, du bestiller, leveres til dig fuldt ud og i henhold til dine specifikationer. Skulle du dog modtage en ufuldstændig ordre eller andre ting end dem, du bestilte, eller der er en anden grund til, at du ikke er tilfreds med ordren, kan du returnere ordren eller produkter inkluderet i ordren og modtage en fuld refusion for varerne. Se fuld returpolitik
Detaljer om produktoverholdelse
Se venligst overensstemmelsesoplysningerne, der er specifikke for dette produkt, beskrevet nedenfor.
Følgende oplysninger leveres af den uafhængige tredjepartsforhandler, der sælger dette produkt.
Producent:
De følgende oplysninger angiver kontaktoplysningerne for producenten af det relevante produkt, der sælges på Fruugo.
- Yixiang Guan
- Shenzhen Xinchuangxiang Trading Co., Ltd.
- Room 201, Building A5, Shenzhen Xiangqian Science and Technology Industrial Park, No. 125-1,Pengda Road, Nanlian Community, Longgang Street, Longgang District
- Shenzhen
- CN
- 518000
- fanyipin_fg@outlook.com
- 18666186861
Ansvarlig person i EU:
De følgende oplysninger angiver kontaktoplysningerne for den ansvarlige person i EU. Den ansvarlige person er den udpegede økonomiske aktør med hovedsæde i EU, der er ansvarlig for overensstemmelsesobligationerne i forbindelse med det relevante produkt, der sælges til den Europæiske Union.
- Axitera GmbH
- Axitera GmbH
- Kreuznacher Str. 30, D-60486
- Frankfurt am Main
- DE
- 60486
- successservice3@gmail.com
- (+49) 6934873848