Digital Timer Delay Relay Switch for DC 6V-30V with Data Save Function Controller

209,00 DKK
+ 99,99 DKK Levering

Digital Timer Delay Relay Switch for DC 6V-30V with Data Save Function Controller

  • Brand: Unbranded
Sоlgt af:

Digital Timer Delay Relay Switch for DC 6V-30V with Data Save Function Controller

  • Brand: Unbranded

209,00 DKK

Spar 120,00 DKK (36%)

Vejl. Pris

329,00 DKK
På lager
+ 99,99 DKK Levering

14-dages returpolitik

Sоlgt af:

209,00 DKK

Spar 120,00 DKK (36%)

Vejl. Pris

329,00 DKK
På lager
+ 99,99 DKK Levering

14-dages returpolitik

Betalingsmetoder:

Beskrivelse

Digital Timer Delay Relay Switch for DC 6V-30V with Data Save Function Controller

DC 12V DDC-431 Timer Delay Relay Switch Digital Data Save Delay Controller DC 6V-30V - Powerful function with one-button emergency stop (STOP button), reverse connection protection, no damage during reverse polarity, power-off memory - Features sleep mode: after 5 minutes of inactivity, display automatically turns off; wake by pressing any button - Supports independent settings for OP, CL, and LOP parameters; settings are saved automatically upon power down, meeting a wide range of application needs Product Manual: Working voltage: DC 6V–DC 30V (wide voltage with reverse polarity protection) Trigger signal source: High-level trigger DC 3.0V–24V; signal ground connected to system ground for improved anti-interference performance; can be shorted to ground Output capacity: DC 30V/10A or AC 250V/10A Product size: 64mm x 35mm x 19.3mm Mounting hole diameter: 3mm Operating temperature: -40°C to 85°C Operating Modes: P1 Mode: After signal trigger, relay turns on for OP time, then turns off. During OP time: P1.1: Signal triggered again P1.2: Signal re-triggers timing P1.3: Signal resets, relay disconnects, timing stops P2 Mode: Upon trigger signal, relay turns off for CL time, then turns on for OP time. After timing completes, relay turns off. P3.1: Trigger signal initiates relay on for OP time, off for CL time, then repeats cycle. Number of cycles (LOP) can be set. If signal is given again during cycle, relay disconnects and timing stops. P3.2: No trigger required after power-on. Relay turns on for OP time, off for CL time, and repeats cycle. Number of cycles (LOP) can be set. P4 Mode: Signal hold function. When trigger signal is present, timing resets and relay remains on. When signal is removed, relay turns off after OP timing. If signal reappears during timing, timing resets. Relay Enable Mode: ON: Relay can conduct during OP time OFF: Relay is disabled and remains off Short press STOP button on main interface to switch between ON and OFF. Current state flashes briefly before returning to main interface. This provides emergency stop functionality. Sleep Mode (long press STOP to view current mode): C-P Sleep Mode: Display turns off automatically after 5 minutes of inactivity; program continues running O-d Normal Mode: Display remains on continuously Press and hold STOP button for 2 seconds to toggle between C-P and O-d modes. Current mode flashes briefly before returning to main interface. Timing Range Selection: After setting parameter in mode selection interface, press STOP button to select timing range: XXX. Decimal point at units place: 1 second to 999 seconds XX.X Decimal point at tenths place: 0.1 seconds to 99.9 seconds X.X.X All decimal points illuminated: 1 minute to 999 minutes Example: To set OP to 3.2 seconds, set decimal point to tenths place; display shows 03.2 Parameters: OP – On time CL – Off time LOP – Cycle count (1–999); 0 indicates infinite loop Parameters are independent and shared across modes. For example, if OP is set to 5 seconds in P1.1, switching to P1.2 will retain OP = 5 seconds unless changed. Display 000 on main interface and press SET button to view OPL, LOP, and corresponding values In modes with only OP (e.g., P1.1, P1.2, P1.3), short press SET to display OP and time In modes with OP, CL, LOP (e.g., P3.1, P3.2), short press SET to display OP, CL, and LOP with respective values After mode setup, press SET on main interface to easily review current mode parameters Parameter Setting Procedure: 1) Determine desired relay operating mode 2) From main interface (module displays current mode on power-up, default P1.1), press and hold SET button for 2 seconds, then release to enter mode selection interface 3) Select desired mode for configuration
  • Fruugo ID: 405214894-859612189
  • EAN: 8324364702694

Levering og returnering

Sendt inden for 3 dage

  • STANDARD: 99,99 DKK - Levering mellem kl fre. 16 januar 2026–man. 26 januar 2026

Afsendes fra Kina.

Vi gør vores bedste for at sikre, at de produkter, du bestiller, leveres til dig fuldt ud og i henhold til dine specifikationer. Skulle du dog modtage en ufuldstændig ordre eller andre ting end dem, du bestilte, eller der er en anden grund til, at du ikke er tilfreds med ordren, kan du returnere ordren eller produkter inkluderet i ordren og modtage en fuld refusion for varerne. Se fuld returpolitik

Detaljer om produktoverholdelse

Se venligst overensstemmelsesoplysningerne, der er specifikke for dette produkt, beskrevet nedenfor.

Følgende oplysninger leveres af den uafhængige tredjepartsforhandler, der sælger dette produkt.

Producent:
De følgende oplysninger angiver kontaktoplysningerne for producenten af det relevante produkt, der sælges på Fruugo.

  • Jiang Yan
  • Guangzhou Ruicai E-commerce Co., Ltd.
  • Room D2709, 203, 2nd Floor, No. 4, Yuejia 2nd Street,Shimen Street, Baiyun District,Guangzhou City,Guangdong Province
  • Guangzhou
  • CN
  • 510420
  • lu61027yeyamei632@163.com
  • 13192975727

Ansvarlig person i EU:
De følgende oplysninger angiver kontaktoplysningerne for den ansvarlige person i EU. Den ansvarlige person er den udpegede økonomiske aktør med hovedsæde i EU, der er ansvarlig for overensstemmelsesobligationerne i forbindelse med det relevante produkt, der sælges til den Europæiske Union.

  • Van Lavazza
  • Y & H S.R.L.
  • Via Gravina 21 MT matera,Trani,Puglia
  • Trani
  • Italy
  • 75100
  • itlyhsrl@gmail.com
  • 0039 3917722149