DC 6V 12V 24V DC Motor Forward And Reverse Regulator 20A High Current Driver Board Limit Relay Lifting Control P0

159,00 DKK
GRATIS Levering

DC 6V 12V 24V DC Motor Forward And Reverse Regulator 20A High Current Driver Board Limit Relay Lifting Control P0

  • Brand: Unbranded
Sоlgt af:

DC 6V 12V 24V DC Motor Forward And Reverse Regulator 20A High Current Driver Board Limit Relay Lifting Control P0

  • Brand: Unbranded

159,00 DKK

Spar 70,00 DKK (30%)

Vejl. Pris

229,00 DKK
På lager
GRATIS Levering
Sоlgt af:

159,00 DKK

Spar 70,00 DKK (30%)

Vejl. Pris

229,00 DKK
På lager
GRATIS Levering

Vi accepterer følgende betalingsmetoder

Beskrivelse

PO version (Self-locking) — Product Description and Key Details Key benefits - Provides reliable self-locking control for motor direction to prevent unintended reversals or stalls. - Simplifies external control: a momentary external forward or reverse command maintains motor motion after the switch is released, reducing operator effort. - Clear, safety-oriented limit behavior: short or transient limit signals reliably stop motion and require intentional restart, avoiding accidental restarts. How it works (functional summary) - PO versions are self-locking: when an external forward switch (K1) is pressed, the motor begins a forward rotation and remains rotating after the switch is released. The motor stops only when a reverse-turn signal (K2) or the forward-turn stop signal (SW1) is received. - Limit (stop) signals are trigger-type, level-activated inputs. If a forward rotation encounters a limit signal, motion is stopped immediately; the motor remains stopped even if the limit signal is removed. To resume forward movement, the forward rotation signal must be issued again. - Signal logic: inputs are active low. The product accepts standard three-wire NPN normally-open (NPN-NO) sensors. Inputs K1, K2, SW1, and SW2 conform to the same active-low specification. Features and attributes - Function: Self-locking directional control with defined limit/stop behavior for safe and predictable motor operation. - Compatibility: Accepts active-low control signals and three-wire NPN-NO sensors; K1, K2, SW1, SW2 are compatible with this signaling convention. - Performance behavior: Latching forward/reverse commands until a definitive stop or opposite command is received; limit inputs act as level-activated stops that persist until a restart command. - Size/material: Refer to the product datasheet or label for exact chassis dimensions and materials used; ensure mechanical compatibility with your installation. - Electrical interface: Designed for active-low control inputs; check system wiring to match NPN-NO sensor outputs or equivalent active-low drivers. Important operational notes - A short or transient limit signal will stop motion immediately and the controller will remain in the stopped state until a new forward or reverse command (as appropriate) is applied. - After a limit-triggered stop, removing the limit signal does not automatically restart motion. - Use sensors and switches that provide active-low outputs (or adapt outputs to active-low) to ensure reliable operation. - K1 = external forward command, K2 = external reverse command, SW1 = forward stop/limit, SW2 = reverse stop/limit (all follow the same active-low/sensor compatibility). Typical applications (practical scenarios) - Automated sliding gate: Use a momentary push-button (K1/K2) or NPN-NO sensor to start forward/reverse motion; SW1/SW2 act as final-limit switches to prevent overtravel. - Conveyor indexing and safety: Motor advances on a forward command and holds until a programmed stop or a limit switch (SW1) is reached; transient limit signals halt the conveyor and require a deliberate restart. - Motorized valve or actuator control: Simple forward/reverse control with reliable stop signals to protect mechanical endpoints and ensure controlled restarts. Compatibility checklist before installation - Confirm control inputs and sensors provide active-low signals or that you can convert them to active-low. - Verify use of three-wire NPN-NO sensors when applicable. - Map external controls to K1 (forward), K2 (reverse), SW1 (forward limit), and SW2 (reverse limit) per the wiring diagram in your product documentation. Safety and troubleshooting tips - Test limit switches and sensors for correct active-low operation before commissioning. - If the motor does not restart after a stop, ensure the appropriate forward/reverse command is reissued (the system will not auto-restart when a limit clears). - Consult the product wiring diagram and electrical ratings before connecting sensors or external switches. This description preserves the PO version behavior and signal requirements: self-locking forward/reverse control, trigger-type level-activated limit signals that latch stop conditions, and active-low input compatibility including three-wire NPN-NO sensors for K1, K2, SW1, and SW2.
  • Fruugo ID: 392781974-840135018
  • EAN: 525287158423

Levering og returnering

Sendes inden for 24 timer

  • STANDARD: GRATIS - Levering mellem kl ons. 03 december 2025–fre. 19 december 2025 - GRATIS

Afsendes fra Kina.

Vi gør vores bedste for at sikre, at de produkter, du bestiller, leveres til dig fuldt ud og i henhold til dine specifikationer. Skulle du dog modtage en ufuldstændig ordre eller andre ting end dem, du bestilte, eller der er en anden grund til, at du ikke er tilfreds med ordren, kan du returnere ordren eller produkter inkluderet i ordren og modtage en fuld refusion for varerne. Se fuld returpolitik

Detaljer om produktoverholdelse

Se venligst overensstemmelsesoplysningerne, der er specifikke for dette produkt, beskrevet nedenfor.

Følgende oplysninger leveres af den uafhængige tredjepartsforhandler, der sælger dette produkt.

Producent:
De følgende oplysninger angiver kontaktoplysningerne for producenten af det relevante produkt, der sælges på Fruugo.

  • DelightDelight
  • Shenzhen Kulomi Technology Co., Ltd.
  • 401-13, Jinhe Building, 8 Xinhe Street, Maan Tang, Bantian
  • Longgang, Shenzhen, Guangdong
  • China
  • Shenzhen
  • CN
  • 518129
  • utopiadealsta@outlook.com
  • 13380310353

Ansvarlig person i EU:
De følgende oplysninger angiver kontaktoplysningerne for den ansvarlige person i EU. Den ansvarlige person er den udpegede økonomiske aktør med hovedsæde i EU, der er ansvarlig for overensstemmelsesobligationerne i forbindelse med det relevante produkt, der sælges til den Europæiske Union.

  • Synertrade FR SAS
  • Synertrade FR SAS
  • 9 rue du Bat d'Argent
  • Lyon
  • France
  • Lyon
  • FR
  • 69001
  • info@syner-sarl.cn
  • (+33)774555006
  • https://seller.kuajingmaihuo.com/settle/qualification-service