Beskrivelse
Features:_x000D_
_x000D_
Writing applications in ladder language support GX-Develoer, GX-WORK2. _x000D_
Support for human-machine interface links, the application is exactly the same as FX3U. _x000D_
Support ladder programming, download, monitor. _x000D_
The programming port is a port for program download and communication with the human machine interface. _x000D_
This PLC adopts industrial-grade 32-bit MCU with strong anti-interference, and its running speed far exceeds the original FX3U. _x000D_
This PLC transmission baud rate is 38400. _x000D_
14-point input and 10-transistor output of the board. _x000D_
Y0-Y3 transistor can output up to 100K pulse. _x000D_
Y4-Y7 transistor can output up to 12K pulse. _x000D_
Y0-Y10 can also be used for ordinary output, which can drive stepping, solenoid valve, cylinder and other DC 24V load. _x000D_
The board is powered by DC 24V. Do not input AC or 220V voltage. _x000D_
_x000D_
Specification:_x000D_
Baud Rate:38400_x000D_
Power Source:24VDC_x000D_
Input power DC 24V _x000D_
Number of steps 8000 steps; 2 communication ports: 1 RS232 (DB9 serial communication port is FX3u protocol 38400, 7, E, 1; 1 RS485 (485 option) (communication protocol can be set D8120) _x000D_
Input point X component XO-X27, DC24 input, active low. X0-5 is the high-speed counting input port (12KHZ) _x000D_
Input point Y component YO-Y3 is the transistor output, the transistor output current is 500mA, plus the freewheeling diode can reach 4A; YO-Y3 is 4 channel 100K pulse output, the output current is 500mA, plus the freewheeling diode can reach 4A.; Y4~Y11 is the transistor common output Can directly drive 24V3A load _x000D_
Analog input 6 analog inputs, 12-bit accuracy, (3 voltages 0-10V, 3 currents 0-20MA); read analog with RD3A instructions _x000D_
Analog output 2 analog outputs, 12-bit accuracy, output voltage: 0-10V. Output analog voltage with WR3A command _x000D_
Intermediate relay M MO-M3071, the power-down storage range can be set to MO-M1023, the default M500-M1023 _x000D_
Step point S S0-1023, the power-down storage range can be set to S0-S1023, the default S500-S9999 _x000D_
100Ms timer TO-T199, cumulative power-down save T184-T199 _x000D_
10Ms timer T200-T249, cumulative power-down save T246-T249 _x000D_
1Ms timer T250-T383, where T250-255 is cumulative _x000D_
16-bit counter CO-C199, save power C100-199 _x000D_
32-bit counter C200-C219, save power C220-C234 _x000D_
32-bit high-speed counter C235-255; C235-240 is a single-phase counter, no multiplier; C241-240 is a single-phase counter, 2 times the frequency; C247-249 is a two-phase counter, no multiplier; C250-252 is a two-phase counter, 2 times Frequency; C253-255 is a two-phase counter, 4 times frequency _x000D_
Register D DO-D7999, the power-down storage range can be set to DO-7999. _x000D_
Indirect addressing pointer V, Z VO-7, Z0-7 _x000D_
P subroutine jump number PO-63 _x000D_
I interrupt XO-5 is interrupted outside. Timer interrupt (1MS is the unit). Counter interrupt _x000D_
Special M component M8000 is normally closed when running, M8002 is powered on pulse, M8011 is 10Ms pulse, M8012 is 100Ms pulse, M8013 is 1s pulse, M8014 is minute pulse. _x000D_
_x000D_
_x000D_
_x000D_
Mnemonic, name Function _x000D_
LD Operation starts normally open contact _x000D_
LDI Operation starts normally closed contact _x000D_
LDP Rising edge detection operation starts _x000D_
LDF The falling edge detection operation starts _x000D_
AND Series normally open contacts _x000D_
ANI Series normally closed contacts _x000D_
ANDP Check the serial connection on the upper edge _x000D_
ANDF Falling edge detection serial connection _x000D_
OR Parallel normally open contact _x000D_
ORI Parallel normally closed contact _x000D_
ORP Rising edge detected parallel connection _x000D_
ORF Falling edge detection parallel connection _x000D_
ANB Series connection between circuit blocks _x000D_
ORB Parallel connection between circuit blocks _x000D_
OUT Coil output drive _x000D_
SET Coil action remains _x000D_
RST Remove line wet motion retention _x000D_
PLS Coil rising edge output _x000D_
PLF Coil falling edge output _x000D_
ALT Alternate output _x000D_
MC Common string connection point with coil command _x000D_
MCR Common contact release command _x000D_
MPS Operational storage _x000D_
MRD Storage readout _x000D_
MPP Storage readout and reset _x000D_
INV The operation result is reversed _x000D_
END End of program _x000D_
_x000D_
4 step ladder instructions _x000D_
STL Step ladder start _x000D_
CALL Call subroutine _x000D_
RET Step ladder end _x000D_
SRET Subroutine return _x000D_
_x000D_
Package List:_x000D_
1 x PLC Controller_x000D_
_x000D_
_x000D_
_x000D_
Note:_x000D_
Please note that the new type and old type of this product will be se
-
Fruugo ID:
310798106-694784540
-
EAN:
6270765406131
Levering og returnering
Sendt inden for 3 dage
Afsendes fra Kina.
Vi gør vores bedste for at sikre, at de produkter, du bestiller, leveres til dig fuldt ud og i henhold til dine specifikationer. Skulle du dog modtage en ufuldstændig ordre eller andre ting end dem, du bestilte, eller der er en anden grund til, at du ikke er tilfreds med ordren, kan du returnere ordren eller produkter inkluderet i ordren og modtage en fuld refusion for varerne. Se fuld returpolitik