Primary Coil Easy To Use Portable Physics Teaching Tool Electromagnetic Induction Solenoid PVC+Brass for Laboratory for School hwy

289,00 DKK
+ 58,99 DKK Shipping

Primary Coil Easy To Use Portable Physics Teaching Tool Electromagnetic Induction Solenoid PVC+Brass for Laboratory for School hwy

  • Brand: Unbranded
Sold by:

Primary Coil Easy To Use Portable Physics Teaching Tool Electromagnetic Induction Solenoid PVC+Brass for Laboratory for School hwy

  • Brand: Unbranded
Price: 289,00 DKK
Sold by:
289,00 DKK
+ 58,99 DKK Shipping

In stock

We accept the following payment methods

Description

Primary Secondary Coil Electromagnetic Induction Coil Experiment Instrument for Physics Teaching Feature: 1. Lightweight and portable, the electromagnetic induction spiral coil specializes in electromagnetic induction phenomena, which is convenient to carry and use. 2. Easy to use, it can be used with bar magnets, ammeters, sliding varistors and other instruments. 3. Physics laboratory equipment auxiliary tools make physics experiment learning more efficient. 4. Rugged and , constructed of enameled copper, wear resistant, not easy to be damaged, and long service life. 5. It is designed to demonstrate electromagnetic induction and verify Lenz's law for students. It is an ideal choice for physics teaching. Specification: Item Type: Electromagnetic Induction Coil Material: PVC+Brass Purpose: Middle and high school physics experiment Applicable Experiments: Study electromagnetic induction, verify Lenz's law, study magnetic induction The outer diameter of the hole at the bottom of the original coil is: Approx. 221mm / 0.90.04in The inner diameter of the hole at the bottom of the original coil is: Approx. 130.5mm / 0.50.02in The height of the round hole at the bottom of the original coil: Approx. 60mm / 2.4in The diameter of the hole at the bottom of the secondary coil is: Approx. 351mm / 1.40.04in The inner diameter of the circular hole at the bottom of the secondary coil is: Approx. 491mm / 1.90.04in The height of the round hole at the bottom of the secondary coil: Approx. 80mm / 3.1in Soft Length: Approx. 85mm / 3.3in How to use: 1. Study the of electromagnetic induction: connect the two ends of the secondary coil B to the two terminals of the ammeter with wires; When using one end of the bar magnet to quickly insert (or withdraw) the secondary coil, the pointers of the galvanometer are all deflected, indicating that there is an induced current in the secondary coil at this time. This is called electromagnetic induction. On the contrary, if the magnet is fixed, the movement of the auxiliary coil will also produce the same 2. Verify Lenz's Law (1) Experimental method: Observe the change in the direction of current indicated in the galvanometer when the magnet is inserted or withdrawn, and when the polarity of the magnet changes; (2) Connect the original coil to a 3-4V DC power supply, and put a single?pole switch and a 109 sliding rheostat in series in the circuit. The same occurs when the original coil is used instead of the magnet to do the above experiment. Changing the direction of current flowing into the primary coil will change the direction of induced current in the secondary coil. (3) According to the device in picture(2), first insert the primary coil into the secondary coil, and then energize the primary coil. When the switch is just turned on or just cut off, the magnetic flux passing through the secondary line diagram changes, which also occurs at this time. The current is induced, and the direction of the current is opposite. Change the direction of the current flowing into the primary coil and redo this experiment, the direction of the induced current in the secondary coil will also change. (4) According to the device in picture (2), insert the primary coil into the secondary coil and connect the circuit, and then use the sliding rheostat to quickly change the current through the primary coil (increase or decrease), and the secondary coil will also be Generate an induced current, and the direction of the induced current is the same as picture (3). Synthesize the above experimental results and analyze it to verify Lenz's law. 3. Study the of magnetic induction Put the primary coil in the above picture 2 device into the secondary coil and wait for it to stand still. There is no induced current in the secondary coil. At this time, insert or withdraw the soft iron C into or out of the central hole of the primary coil, the soft iron is magnetized, and the magnetic field Increase or decrease. The change in the magnetic flux in the secondary coil also generates induced current. This experiment can explain both the magnetic induction and electromagnetic induction phenomena. During the experiments in the device picture (2), insert the soft iron into the center hole of the original line diagram for demonstration, and the induced current in the secondary coil will increase the effect more obviously. Package List: 1 x Primary Coil A 1 x Secondary Coil B
  • Fruugo ID: 404103955-857697333
  • EAN: 3694560095360

Delivery & Returns

Dispatched within 24 hours

  • STANDARD: 58,99 DKK - Delivery between Mon 27 October 2025–Mon 03 November 2025

Shipping from China.

We do our best to ensure that the products that you order are delivered to you in full and according to your specifications. However, should you receive an incomplete order, or items different from the ones you ordered, or there is some other reason why you are not satisfied with the order, you may return the order, or any products included in the order, and receive a full refund for the items. View full return policy

Product Compliance Details

Please see the compliance information specific to this product outlined below.

The following information is provided by the independent third-party retailer selling this product.

Manufacturer
The following information outlines the contact details for the manufacturer of the relevant product sold on Fruugo.

  • Shenzhenyuandedianziyuouxiangongsi
  • Shenzhenyuandedianziyuouxiangongsi
  • Room 1401-04 Yousuo Bldg 2000
  • Jiaxian Road Gangtou Community
  • Bantian Subdistrict
  • Shenzhen
  • China
  • 518500
  • szrhkj41@163.com
  • 15819859068

Responsible Person in the EU
The following information outlines the contact information for the responsible person in the EU. The responsible person is the designated economic operator based in the EU who is responsible for the compliance obligations relating to the relevant product sold into the European Union.

  • Huang Pengliang
  • FORCHAIN GmbH
  • Vilbeler Landstra?e73 60388 Frankfurt am Main
  • Frankfurt am Main
  • Frankfurt am Main
  • DE
  • 60388
  • nnicolesusan093@gmail.com
  • 1638127736